Start with annual load, not floor area

An annual load is the amount of heat the system must move over a year, measured here in Btu. Equipment capacity is measured in Btu per hour. The two are easy to confuse, but a capacity label cannot tell you annual use. Square footage cannot tell you either: insulation, air leaks, ducts, weather and how you use the house all affect the load. Use annual figures from a building-specific analysis if you have them. The calculator's DOE/FEMP cases are for exploring the math.

Calculate electricity for each season

Cooling kWh = annual cooling Btu ÷ SEER2 ÷ 1,000
Heating kWh = annual heating Btu ÷ HSPF2 ÷ 1,000
Annual electricity cost = (cooling kWh + heating kWh) × USD/kWh

SEER2 and HSPF2 are seasonal ratings in Btu per watt-hour. The extra division by 1,000 changes watt-hours to kilowatt-hours. The calculator rounds the displayed result, after doing the arithmetic at full precision. The method page lists the assumptions.

Choose a price that answers your question

The state selector uses the U.S. Energy Information Administration's final 2025 residential annual average. Your bill may show a different rate. Enter that rate if it better fits the question you are asking. Both options use the same constant price; time-of-use charges, fixed fees and future rate changes are outside this calculation.

Compare all state averages or open a pilot state page for five years of EIA prices and DOE example costs. Every state page uses the same example loads.

Read the result as a scenario

The annual figure covers modeled heating and cooling electricity for a ducted air-source heat pump. Installation, maintenance, backup heat, other household electricity and taxes are outside it. Actual operation can differ from seasonal ratings. To include installed prices, enter both quotes in the calculator. A blank quote never becomes $0.

Ask how each proposed system was sized, then check the work included in each quote.